Make Your Industrial Purchase Cheaper, Faster, Easier, and Better
伊伊西科技(北京)有限公司
EEC TECHNOLOGY (BEIJING) CORP., LTD

  Hot Line

  +86 134 6671 4221​

P
Hot Search: CK-625, CCGS, CWM-75L, TV1547, 9T94A, ITL12-1, FN1000, GM2200, DA7250, IM9500 ...
P​​
                     
               
CURRENT LOCATION:​​​
 产品中心​TECH 
SGB.DGB series dry isolation transformer

SGB.DGB series dry isolation transformer

It is mainly used in power supply places where AC 50-60Hz and input voltage does not exceed AC1140V. It is widely used in high-speed rail, subway, high-rise buildings, airports, stations, terminals, enterprises and tunnels, etc., which need to change voltage and safety isolation.

0.00
0.00
  
商品描述

It is mainly used in power supply places where AC 50-60Hz and input voltage does not exceed AC1140V. It is widely used in high-speed rail, subway, high-rise buildings, airports, stations, terminals, enterprises and tunnels, etc., which need to change voltage and safety isolation.




SGB.DGB series dry isolation transformer technical parameters

Capacity

1KVA-3000KVA

Voltage level

  AC1140V and below

Input voltage

Allowable ±10% fluctuation in rated voltage

Insulation resistance

DC 500V100MΩ

Output voltage

Rated voltage within the load range ±2-3

Insulation class

F class

Frequency

50Hz/60Hz

Ambient temperature

15°C--+45°C

Dielectric strength

3500V/10mA/60s

Relative humidity

95

Load performance

Can withstand 3 times instantaneous current when continuous 100c/o full load

Temperature rise

100K

Waveform distortion

No additional waveform distortion

Noise

55db




Specification model

Model

Rated Capacity

Rated input

Rated output

Reference Size

Reference weight

KVA

Line/phase voltageV)

Line/phase voltageV)

Width X deep X heightmm

KG

Three phase

SGB-3

3

AC1140V/660V

And below

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC3000V/1720V

And below

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

325×120×260

32

SGB-5

5

325×145×260

40

SGB-10

10

340×200×330

60

SGB-15

15

420×240×390

90

SGB-20

20

420×250×410

110

SGB-30

30

420×350×410

130

SGB-40

40

480×300×460

170

SGB-50

50

650×400×540

210

SGB-60

60

650×420×540

230

SGB-80

80

650×380×600

320

SGB-100

100

650×400×600

380

SGB-120

120

800×450×600

420

SGB-150

150

850×380×780

500

SGB-180

180

850×380×780

550

SGB-200

200

850×430×780

620

SGB-225

225

855×435×780

680

SGB-250

250

860×440×780

730

SGB-300

300

870×445×780

820

SGB-400

400

890×450×780

950

SGB-500

500

1050×600×1200

1300

SGB-600

600

1100×700×1200

1500

SGB-800

800

1120×750×1200

1800

SGB-1000

1000

1150×800×1200

2100

single-phase

DGB-1

1

Phase voltage

AC1140V

And below

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase voltage

AC3000V

And below

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

165×140×140

12

DGB-2

2

200×130×210

16

DGB-3

3

200×140×210

18

DGB-5

5

210×170×280

28

DGB-8

8

210×190×300

36

DGB-10

10

210×220×300

43

DGB-12

12

240×170×380

47

DGB-15

15

250×180×380

55

DGB-20

20

250×220×380

77

DGB-25

25

250×230×440

100

DGB-30

30

250×230×550

120

DGB-40

40

260×250×550

140

DGB-50

50

330×240×550

170

DGB-60

60

330×280×550

210

DGB-80

80

330×320×550

260

DGB-100

100

340×320×550

300

DGB-120

120

440×400×600

360

DGB-150

150

450×420×600

410

DGB-180

180

560×440×780

470

DGB-200

200

580×445×780

520


Note: The above is a regular model, EECTECH can customize special specifications according to customer requirements.


For more information, please contact EECTECH










1. SGB (DGB) series three-phase (single-phase) dry isolation transformer is a multi-coil (double coil and above) structural transformer. The primary and secondary windings are insulated from each other, and the transformation ratio is fixed and Two types of taps can be boosted or stepped down. In addition to changing the voltage, the isolation transformer can electrically isolate the input winding and the output winding from each other to avoid the danger of touching the charged body (or metal parts that may be charged due to insulation damage) and the ground; The isolation transformer also has a certain effect of suppressing various interferences.

2. The main functions of SGB (DGB) series three-phase (single-phase) dry isolation transformer:

   1). Electrical safety isolation
   
2). Change the voltage level
   
3). Overcome the drift of the center point and improve the power imbalance
   
4). Anti-surge impact and filtering function.

3. SGB (DGB) series three-phase (single-phase) dry isolation transformer is mainly used for AC 50-60Hz, input voltage does not exceed AC1140V power supply, widely used in high-speed rail, subway, high-rise buildings, airports, stations, terminals, Enterprises, tunnels and other transmission and distribution sites that need to change voltage and safety isolation, product rated input voltage, rated output voltage, connection group, tap winding capacity distribution, etc., can be carefully designed and manufactured according to user requirements.

4. SGB (DGB) series three-phase (single-phase) dry isolation transformers should be used indoors. The normal conditions of use are:
   
1), ambient temperature: -15 ° C - +45 ° C
   
2), altitude: <1000M
   
3) Relative humidity: < 95%
   
4) There are no gases, vapors, chemical deposits, dirt and other explosive and corrosive media that seriously affect the insulation of the transformer.
   
5) There is no serious vibration or bumps in the installation site.







Send Inquiry​​