SBW high power regulator is suitable for a wide range of loads and can withstand transient overload. SBW high power regulator can work continuously for a long time, manual/automatic switching
SBW high power regulator is suitable for a wide range of loads and can withstand transient overload. SBW high power regulator can work continuously for a long time, manual/automatic switching
Compensated power regulator technical parameters
Input
Allowable input voltage range
3Φ4W+G AC380V±20%, wide range can be customized
Rated voltage regulation range
3Φ4W+G AC380V±15%, wide range can be customized
Rated frequency
50HZ/60HZ
Output
Rated output voltage
3Φ4W+G line voltage AC380V (phase voltage AC220V)
Center voltage
±5% adjustable (line voltage AC360V-400V adjustable)
Voltage regulation accuracy
±(1-5)% selectable, factory setting: line voltage Uab±6V (±1.5%)
Response time
≤0.1s
Stable schedule
≤1s(The input voltage is changed by 10% from the rated value step)
Waveform distortion
Increment≤0.5%
Efficiency
250KVA and below ≥97%; above 250KVA ≥98%
Three-phase unbalance
Increment≤0.5%
Protection
Overpressure
The output line voltage is higher than the set value of 10%, and the alarm is delayed by 6 seconds to cut off the output; (overvoltage value and delay time can be set according to user requirements)
Undervoltage
The output line voltage is lower than the set value of 12%, and the alarm is delayed by 12 seconds to cut off the output; (the undervoltage value and delay time can be set according to user requirements)
Overload
Double detection of electronic detection and circuit breaker (cannot be set according to the model); exceed the rated load long delay, and cut off the output power according to the inverse time curve
Overcurrent
Double detection of electronic detection and circuit breaker (can be adjusted according to the model and approved); exceeds the rated current by 1.2 times and has a short delay of 20 seconds, and cuts off the output power according to the inverse time curve.
Short circuit
Circuit breaker protection: instantaneous cut off output
Bypass
Power supply manual through device when the regulator is faulty or repaired
Display and alarm (blue LCD screen)
Input voltage display
Manually switch display (or automatic wheel display); current three-phase input line voltage UAB, UBC, UCA (true RMS digital display)
Output voltage display
Manually switch display (or automatic wheel display); current three-phase output line voltage Uab, Ubc, Uca (true RMS digital display)
Working current display
Manually switch display (or automatic wheel display); current three-phase operating current values Ia, Ib, Ic (true RMS digital display)
Work status display and alarm record
a. Overvoltage (Up): When the output line voltages Uab, Ubc, and Uca appear Up, it indicates that the phase has an overvoltage, and the “Alarm” alarm prompt and alarm tone will appear at the same time in the lower right corner.
b. Undervoltage: When the output line voltages Uab, Ubc, and Uca appear Down, it indicates that the phase has an undervoltage, and the “Alarm” alarm prompt and alarm tone will appear at the same time in the lower right corner.
c. Overload: When Ia, Ib, and Ic appear Up, it indicates that the phase is overloaded, and the “Alarm” alarm prompt and alarm tone will appear at the same time in the lower right corner.
d. When the “Alarm” alarm prompt and alarm tone appear in the lower right corner, it indicates that the current alarm is not released. You can check the fault record value and press the “Mute” membrane button to mute.Control parameter setting
SCM intelligent detection control
The intelligent detection and control of the single-chip microcomputer: detecting the input voltage, output voltage and working current of the voltage regulator, a total of 9 power signals, after being converted into digital signals by AD, the corresponding control, display and alarm signals are issued after the intelligent judgment of the single-chip microcomputer.
parameter settings
Voltage regulation accuracy can be set
Output voltage center value can be set
Overcurrent protection value and delay time can be set (requires manufacturer approval)
Overvoltage protection value and delay time can be set
Undervoltage protection value and delay time can be set
Manual voltage regulation / automatic voltage regulation can be switched
Safety regulations
Earthing
Grounding is reliable and the marking is correct and clear
Clearance and creepage distance
Greater than 10MM
Insulation resistance
The whole machine is ≥2MΩ to ground (excluding control and instrument display)
Dielectric strength
Machine to ground: AC2000V 50HZ 1 min ≤ 20mA (excluding control and instrument display)
Input and output wiring
The logo is correct and clear
Way of working
With voltage regulator and utility power
Voltage adjustment method
Intelligent (microcomputer control) compensation
Overload capability
Less than 1.2 times rated current 15 minutes; 1.2-2 times rated current 20 seconds; 3 times rated current 1 second
Optional features (additional cost)
1. Delay output function (increased output contactor);
2. Lightning protection device: It can provide good surge protection when the power grid changes instantaneously and inductive lightning strikes; 3. EMI filter device: It can effectively filter the harmonic interference of the power grid;
4. Phase sequence and phase loss protection;
5. RS485 interface: realize remote control, remote signaling and telemetry.
Specification model
Model
Rated Capacity (KVA)
Rated current (A)
Cabinet dimensions(mm)
Weight
Width X Thickness X Height (W x D x H)
(kg)
SBW-S-20
20
30
600*600*1200
165
SBW-S-30
30
46
175
SBW-S-50
50
76
200
SBW-S-60
60
91
210
SBW-S-80
80
121
650*680*1280
230
SBW-S-100
100
152
250
SBW-S-120
120
182
280
SBW-S-150
150
228
700*850*1500
340
SBW-S-180
180
273
380
SBW-S-200
200
300
400
SBW-S-225
225
342
465
SBW-S-250
250
380
485
SBW-S-320
320
486
800*900*1700
580
SBW-S-400
400
608
660
SBW-S-500
500
760
900*1100*1800
830
SBW-S-600
600
912
920
SBW-S-800
800
1216
1000*1200*2000
1100
SBW-S-1000
1000
1520
(1200+1200)*900 *2200 (Two cabinets)
1700
SBW-S-1200
1200
1824
1900
SBW-S-1400
1400
2127
2200
SBW-S-1600
1600
2431
(1200+1100+1400)*900*2200(three cabinets)
2700
SBW-S-2000
2000
3038
(1400+1100+1100+1400)*900*2200(four cabinets)
3500
SBW-S-2500
2500
3800
(1550+1200+1200+1550)*900*2200(four cabinets)
4200
SBW-S-3200
3200
4862
(1500+1500+1500+1500+1500)*1000 *2200(Five cabinets)
5700
DBW-S-10
10
45.4
600*600*1200
150
DBW-S-15
15
68.2
155
DBW-S-20
20
91
160
DBW-S-30
30
136
180
DBW-S-40
40
182
190
DBW-S-50
50
228
650*680*1280
210
DBW-S-60
60
273
650*680*1280
220
DBW-S-80
80
363
650*680*1280
260
DBW-S-100
100
454
700*850*1500
310
Note: The above are regular models, which can be customized according to customer needs.
For more information, please contact EECTECH
1. SBW series three-phase automatic compensation type power regulator is designed to stabilize AC voltage. When the external power supply network voltage fluctuation or load changes cause voltage fluctuations, the output voltage can be kept stable.
2. Compared with other types of voltage regulators, SBW series regulators have the advantages of large capacity, high efficiency, no waveform distortion, stable voltage regulation, etc. SBW high-power regulators are suitable for a wide range of loads and can withstand transient overload, SBW High-power voltage regulator can work continuously for a long time, manual/automatic switching. SBW high-power voltage regulator is equipped with over-voltage protection, phase loss, phase sequence protection and automatic mechanical fault protection, as well as small size, light weight and easy installation. , reliable operation and so on.
3. SBW high-power voltage regulator can be widely used in industrial, agricultural, transportation, post and telecommunications, military, railway, scientific research and other fields of large-scale electromechanical equipment, metal processing equipment, production lines, construction engineering equipment, elevators, medical equipment, embroidery Light textile equipment, air conditioners, radio and television, household appliances, lighting, etc., where voltage regulation is required.
4. SBW series regulators should be used indoors. The normal operating conditions of SBW regulators are:
1), ambient temperature: -10 ° C -45 ° C
2), altitude: <1000M
3) Relative humidity: 20%-90%
4) There are no gases, vapors, chemical deposits, dust, dirt and other explosive and corrosive media that seriously affect the insulation of the regulator.
5), SBW series regulator installation site without serious vibration or bumps.